nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 29, 2009, 6:13 am
ermDefinitionLinkA Link is the logical medium by which H1 Fieldbus devices are interconnected. It is composed of one or more physical segments interconnected by bus Repeaters or Couplers. All of the d... Comment - Like
nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 29, 2009, 6:00 am
TermDefinitionAcyclic PeriodThe Acyclic Period is that portion of the communication cycle time, during which information other than Publish/Subscribe data is transmitted. Typical information transmitt... Comment - Like
nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 23, 2009, 4:28 pm
FOUNDATION Fieldbus Developer Training To Be Offered During October In Austin, TexasVendor-neutral instruction covers key aspects of Foundation technology
AUSTIN, Texas, August 18, 2009 – The Fieldb... Comment - Like
nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 23, 2009, 4:06 pm
Fieldbus (the use of digital communications networks for distributed instrumentation and control) is a wonderful technology with many benefits, but fieldbus installation requires some additional consi... Comment - Like
nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 23, 2009, 3:35 pm
FOUNDATION™ fieldbus - the path to the future
The Internet is having a major impact on information flows. Yesterday's hierarchical systems with vertical information flows are being replaced... Comment - Like
nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 17, 2009, 11:44 am
The maximum permissible bus length depends on the transmission rate and the bus cable type. Different cable types (designation A to D) for different applications are available for connecting PROFIBUS ... Comment - Like
nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 17, 2009, 11:37 am
Bus length and speedWhen a PROFIBUS network is installed, boundary conditions of the RS485 transfer technology must be observed. The electrical network uses a shielded, twisted pair cable. All subscri... Comment - Like
nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 17, 2009, 11:30 am
Using a redundant PROFIBUS system makes it possible to considerably increase the availability and thus the reliability in comparison with a single system. One particular advantage is scalable redundan... Comment - Like
nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 17, 2009, 11:20 am
Line TopologyWith this topology, the fieldbus cable is routed from device to device on this segment, and is interconnected at the terminals of each fieldbus device. Installations using this topology s... Comment - Like
nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 17, 2009, 11:12 am
The PROFIBUS DP (RS485) is responsible for communication between the Controller level of a process automation system and the decentralized periphery in the field, also intrinsic safety (RS485-IS) via ... Comment - Like
nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 17, 2009, 10:47 am
PROFIBUS is a manufacturer-independent field bus standard for applications in manufacturing, process and building automation. PROFIBUS technology is described in fixed terms in DIN 19245 as a German s... Comment - Like
nour nabil posted an article on
smart industrial solutions for automated systems
-
Aug 16, 2009, 7:48 am
Automation.com - Industrial Automation, Factory & Process ...
Industrial Automation INSIDER Homepage
Department of Automation, Tsinghua University
Process Control and Instrumentation - Industrial Auto... Comment - Like